    Type III

    Type III

    1. FEATURES AND SPECIFICATIONS
    The Type Intelligent Battery Guard continually monitors the battery charge, and automatically disconnects the battery from the electricity system if it detects that the power is falling below the level that is required to start the engine. The power will be reconnected by pressing and releasing the RESET button of the remote control.

    Package Contents


    Tools Required

    Installation Steps
    Step 1:Turn the ON/OFF yellow knob on the top of the unit to the ON position  


    Step 2: Disconnecting The Battery Cables

    A)  Disconnect the black negative cable from the negative post on the battery.
    B)  Disconnect the red positive cable from the positive post on the battery.


    Step 3: Connecting the Intelligent Battery Guard

    A:  Connect the Positive Clamp set on the positive side of the Intelligent Battery Guard, the
          positive side of the Intelligent Battery Guard is located on the side of the unit that has 12V+
          printed on it.
    B:  Connect the Aluminum Positive Post set on the other side of the Intelligent Battery Guard.
    C:  Connect the positive clamp onto the battery.


    A:  Connect the red/positive battery cable to the aluminum post on the outer bracket of the
          Intelligent Battery Guard.
    B:  Connect the black negative battery cable to the negative post on the battery.
    C:  Connect the clip end of the black ground wire to the clamp bolt on the negative post on
          the battery.


    Step 4: Accessory Bypass Wire Installation

    A.  Slide the connecter end of the Bypass wire onto the Butterfly Connector On the female positive
          post of Intelligent Battery Guard.
    B.  Locate the motor's fuse box and the desired fuse.
    C.  Remove the fuse and insert it into the fuse connection in the bypass wire.
    D.  Connect the exposed end of the bypass wire into the outbound leg of the fuse box to activate
          the device.


    Step 5: Disabling connection/motor on wire installation 

    A.  Locate a fuse in the fuse box that has current when the motor is turned on and no current when
         the motor is turned off. This wire can be connected directly to the key switch.
    B.  Remove fuse.
    C.  Connect the exposed end of the bypass wire into the fuse box.
    D.  Slide the connector end of the bypass wire onto the single connector on the negative side of
          the Intelligent Battery Guard. The connector is marked ACC .


    3. TEST INSTALLATION RESULT

    To test successful installation
    Start the vehicle after installation is completed.

    To test Intelligent Battery Guard operation
    Turn the Vehicle off and turn on as many electrical accessories (i.e. lights, radio,) as possible and leave them on. The intelligent Battery Guard will cut power form the battery automatically confirming it is working. This may take some time, depending on the battery's age and charge.

    To test manual reset function
    Ensure that the yellow Manual reset control knob is in the ON position and press it down after the Intelligent Battery Guard had disconnected the power, the unit should re-establish power to the electrical accessories and enable you to start the vehicle.

    Remote control instructions and test:
    Let's introduce all buttons & functions of the remote control unit and test the functions:


    1.  Lock Symbol button Disconnect.  Press and hold this button for 2 seconds in order to
         disconnect power between the vehicle and the battery. The unit then becomes an antitheft
         device and could not start.
    2.  Unlock symbol button Reconnect. Press and hold the reset button for 2 seconds in order
         to reconnect the unit and start the vehicle.

    4. IMPORTANT NOTICE
    If a warning light for NO CHARGE or BATTERY WARNING illuminates on your vehicle dashboard, stop your vehicle at a safe area and turn the yellow knob to one of OFF positions, your vehicle will experience a complete loss of power unless the NO CHARGE problem is repaired immediately! This problem is unrelated to the intelligent Battery Guard and requires assistance from an Auto Technician.