R407C Refrigerant Dry Heat Exchanger Water - Source Heating Pump System

Categories Dry Heat Exchanger
Brand Name: GREEFOUN
Model Number: QXE140
Certification: CE
Place of Origin: CHINA
MOQ: 1piece
Payment Terms: T/T, L/C, Western Union
Supply Ability: 100000pieces/year
Delivery Time: within 15days
Packaging Details: Standard export package
Refrigerant: R407C
Refrigerating medium: Underground water
Shell material: Steel pipe
Cooling capacity: 18KW~4000KW
Circuit: Single circuit
Heat exchange tube: Copper tube
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    R407C Refrigerant Dry Heat Exchanger Water - Source Heating Pump System

    R407C Refrigerant Dry Heat Exchanger Water - Source Heating Pump System


    Ground source heat pump is a kind of central air conditioning, ground source heat pump central air


    conditioning system is the use of shallow surface water (such as groundwater, rivers and lakes) and the


    soil source of solar and geothermal energy absorption, and the use of heat pump principle, Hot and can


    be cooled and efficient energy-saving central air conditioning system.


    Ground source heat pump central air conditioning system is the use of shallow to the heating and cooling


    of the new energy use technology, is a heat pump, the use of Carnot cycle and reverse Carnot cycle


    principle of the transfer of cold and heat equipment.


    Ground source heat pump usually refers to the transfer of underground soil heat or cold to the required


    place.


    Usually heat pumps are used for air conditioning or heating. Ground source heat pump also uses the


    underground soil huge heat storage capacity, the winter source of heat from the underground soil transfer


    to the building, the summer and then the underground cooling capacity transferred to the building, an


    annual formation of a hot and cold cycle


    DRY TYPE TUBE HEAT EXCHANGER EVAPORATOR (DOUBLE MACHINE)


    CAPACITY: 120KW TO 310KW

    ModelsQXU120D8QXU135D8QXU155D8QXU185D10QXU220D10QXU270D10QXU310D10

    Rated data
    Refrigerant R22

    ti=12°C te=2°C

    tu=7°C Dts=5°C

    QnKW120135155185220270310

    Kcal/h

    (×103 )

    103.2116133.3159189232267
    Wnm3 /h20.623.226.731.837.846.453.3
    Wmm3 /h25283041436568
    Dpnbar0.410.440.370.360.430.420.43

    ModelsQXU120D8QXU135D8QXU155D8QXU185D10QXU220D10QXU270D10QXU310D10

    Dimension

    (mm)

    A1815211523152320232026542654
    B219219219219273273273
    C200200200200234234234
    D1530183020302000200022802280
    E240240240300300300300
    VentS11/21/21/21/21/21/21/2
    OutletS21/21/21/21/21/21/21/2
    ConnectionW(DN)89898989114114114
    D1(mm)22222222353535
    D2(mm)42424242545454
    P(kg)145155163232255279296

    Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

    Dpn-pressure drop of recirculating cooling water Dts-overheat temperature


    FULL LIQUID TYPE EVAPORATOR AND CONDENSER EXTERNAL OIL


    (DOUBLE CIRCUIT) CAPACITY: 800KW TO 2200KW


    ModelsQX-800MQX-950MQX-1200MQX-1380MQX-1600MQX-1900MQX-2200M
    Refrigerant R22 (or other environmental refrigerants)Refrigerating capacity (KW)80096012001380160019002200
    Heating capacity (KW)950114014001650200023802650
    Wam3/h138165.5207238276327.5379
    Wbm3/h192206259297344400473
    Dpnbar0.710.730.750.760.790.820.84

    ModelsQX-800MQX-950MQX-1200MQX-1380MQX-1600MQX-1900MQX-2200M
    Dimension(mm)A3909390939093909424542454245
    A1450500500500500500500
    A2360400400400400400400
    L12032203220322032220022002200
    B1340144014701470147015701570
    B1690740755755755805805
    C192597510081008100810581058
    C292597510081008100810581058
    D1426480480480480530530
    D2480530566566566616616
    H1300350350350350350350
    H2260280280280280350350

    Inlet/Outlet (diameter)

    Connection

    a/b(DN)150200200200200200200
    c1-4 (mm)35424242424242
    d1-2(mm)929292929292105
    D3-4(mm)67676780808080
    Corresponding external oilVolume (L)90*295*2100*2110*2130*2160*2180*2
    WeightP (KG)1745200625702780314034803610

    Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water

    Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C

    Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C.