Sign In | Join Free | My chinaqualitycrafts.com
chinaqualitycrafts.com
Products
Search by Category
Home > Emergency & Clinics Apparatuses >

Flow Meter Health Care Digital Medical Oxygen Tank Regulator / Medical Gas Regulators

Categories Medical Oxygen Regulator
Brand Name: TWA
Model Number: YR-86-29
Certification: DOT
Place of Origin: China
MOQ: Negotiate
Price: Negotiate
Supply Ability: 100000 Piece/Pieces per Month
Delivery Time: 15-20days
Packaging Details: Carton
Medium: oxygen
Inlet connection: G5/8'-RH(M)
Output connection screw threda: 8mm
Mettering range (L/min): 1-10or 1-15
MAX.discharge pressure :: 0.2-0.3MPa
Outer connection: Nasal oxygen cannula
Accuracy:: Grade 4
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Flow Meter Health Care Digital Medical Oxygen Tank Regulator / Medical Gas Regulators

    Medical Oxygen Regulator Buoy Type Oxygen Inhalator YR-86-29
    specifications:


    NameDigital medical OxyEn Regulator With Flow Meter Health Care Product
    TypeYR-86-29
    GasO2
    Input pressure15MPa
    Output pressure0.2 ~ 0.3MPa
    Flow control range1-10L/Min , 1-15L/Min
    valve pressure range0.35 ± 0.05Mpa
    Output connection screw thread8mm
    Valve materialBrass
    Pressure gauge50mm
    Bottle materialPVB
    Humidifier capacity200ml
    delivery time15-25 days


    Application:

    Medical regulator is used for oxygen breathing in hospital

    TypeMedium

    Mettering range
    (L/min)

    Accuracy

    Entrance
    Pressure
    (MPa)

    Exit
    pressure(MPa)

    Entrance connection screw thredaOutput connection screw threda
    YR-86(A)O21-10or 1-15grade4

    12MPa

    0.2-0.3MPa

    G5/8-14-RH
    CGA540-RH
    G3/4-14-RH

    8mm


    Description:

    welding regulator, for oxygen, we also have other types of regulators for ,acetylene,
    ARGON,CO2 gases

    1. Forged brass body; bonnet for maximum strength.
    2. Oxygen safety relief valve is set for safe operation.
    3. Sintered metal inlet filter to trap impurities.
    4. No soldered joints, for easy maintenance.
    5. Easy to read dual scale gauges (BAR/P.S.I) with virtually unbreakable crew-on lean lens
    6. Gauges meet EN 562 and BAM approved dual scale (Bar/Psi) and marked for maximum
    working pressure.
    7. Models are available for 200 or 300 Bar Max. inlet pressure.




    Mainly function :
    Oxygen flow range:1-10L/Min 1-15L/Min
    Pressure reducing range:2.0-3.0kg
    Relief valve pressure range :(3.5kg+0.5kg
    Appliance introduction :
    1. Before using ,please fill pour clear water into moisture bottle about one third reaching water
    ine site.
    2. DF-2 blind nut straw into bolt head ,make the pipe of flow meter square water line.
    3. Put off regulator (9),put on oxygen tube switch ,so you will the data from needle position of pressure gauge (2).At last ,straw flow on/off at anti-clock wise accroding to patients need,
    adjust switch.
    4. If patient need oxygen for a long time ,can use nose pipe to help patient absorb oxygen.
    5. Moisture bottle(20) circles at clockwise,adjust (17)oxygen hole to other site.
    Attention point :
    1. Before using the suction ,you will check all parts bad or good and clean it by drying choth .
    2. Pressure gauge (2),regulator(3) no oil ,otherwise explode.
    3. Clearwater in moistyre bottle keeps clean.
    4. There is adjustable nut(6) in the front of plunder shall be straw at clockwise .
    5. Relief value(7)(15) keeps out of danger.
    6. Oxygen dosage is decided by doctor.
    7. After using suction,put off the oxygen tube switch,make rest oxygen out,pressure gage to
    zero site,last put off flow switch if using again,first put on the oxygen tube switch,avoid
    exploding.
    8. The product must be examined periodical,at least once every 6 month.

    Packaging & Shipping:
    About packing: Annual package
    About our shipping:
    1. The parts normally will be shipped out within 30 working days after the payment
    confirmed.
    2. The parts can also be shipped by DHL/TNT/UPS/EMS/FedEx, you are welcome to
    choose the way you like.
    3. We are not responsible for any accidents, delays or other issues caused by the forwarder.
    4. Any import fees or charges are afforded by buyers.

    Advantage:

    1. Low MOQ: It can meet your promotional business very well.
    2. OEM Accepted: We can produce any your design.
    3. Good Service: We treat clients as friend.
    4. Good Quality: We have strict quality control system .Good reputation in the market.
    5. Fast & Cheap Delivery: We have big discount from forwarder (Long-term Contract).

    Buy Flow Meter Health Care Digital Medical Oxygen Tank Regulator  / Medical Gas Regulators at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Shanghai Qilong High Pressure Container Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0