Sign In | Join Free | My chinaqualitycrafts.com
chinaqualitycrafts.com
Products
Search by Category
Home >

40KW Natural Gas Heat Pump Air Conditioner GHP High Reliability

Categories Gas Heat Pump Air Conditioner
Brand Name: Kingway
Model Number: KW40NHCSW
Certification: CE, ISO, ROHS
Place of Origin: Shandong, China
MOQ: 1 Set
Payment Terms: L/C, T/T, Western Union, D/P
Supply Ability: 300 Sets Per Year
Delivery Time: 20 Working Days
Packaging Details: Wooden Carton, PE Film
Product: 40KW Natrual Gas Heat Pump ( GHP )Air Conditioner
Color: Customized
Warranty: 12 months/ 1000 working hours
Fuel: Natural Gas ( NG)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    40KW Natural Gas Heat Pump Air Conditioner GHP High Reliability

    40KW Natural Gas Heat Pump ( GHP )Air Conditioner


    What is a gas heat pump air conditioner?
    The gas heat pump air conditioner is an air conditioning unit that drives the compressor through a gas engine and circulates the gas heat pump for cooling or heating.


    The difference between the gas heat pump air unit and the air source heat pump air conditioner is: the gas V heat pump air conditioner uses the TN city gas as the energy source: the air source heat pump air conditioner is driven by the built-in motor of the compressor, driven by the gas engine, and uses the gas as the energy source: the work uses electricity as the energy source .Self-developed GHP special gas engine.


    ModelKW40NHCSW-1/1AKW65NHCSW-1/2AKW71NHCSW-1/2AKW120NHSW-1/2A
    Power supply1N~220V 50Hz1N~220V 50Hz1N~220V 50Hz1N~220V 50Hz

    Performance

    Nominal cooling capacity(KW)406571-
    Refrigeration condition heat recovery (KW)233740-
    Heating CapacityNominal Capacity (KW)457380120
    Low Temperature (KW)457380120
    Gas consumption (low calorific value)Gas typeNatural gasNatural gasNatural gasNatural gas
    Nominal cooling (KW)33.754.859.9-
    Nominal heating (KW)33.955.160.265
    Electrical CharacteristicsRefrigerationRunning current (A)4.687.608.30-
    Power consumption (KW)0.951.541.68-
    HeatingRunning current (A)4.397.147.8012
    Power consumption (KW)0.881.441.572.1
    Water flowRefrigeration (M3/h)6.8811.1812.21-
    Heating (M3/h)6.8811.1812.2120.64
    Domestic hot water (M3/h)3.886.306.88-
    CompressorTypeVortex *1Vortex *2Vortex *2Vortex *2
    Displacement86.286.286.286.2
    Lubricant grade (Cm3/rev)FVC68DFVC68DFVC68DFVC68D
    Refrigerator oil charge (L)2*12*22*22*2
    Crankshaft heating belt (W)40*140*240*240*2

    Engine


    Range of rotation (RPM)1000~23001000~23001000~23001000~2300
    Displacement (cc)2300230023002300
    Engine oil grade5W-405W-405W-405W-40
    Lubricating oil charge (L)23454545
    Start methodDC Electric StartDC Electric StartDC Electric StartDC Electric Start
    Engine cooling waterPump power (W)152252252252
    Charge (L)20323232
    Concentration, freezing temperature50V/V%~ -35°C50V/V%~ -35°C50V/V%~ -35°C50V/V%~ -35°C
    Refrigerant (R410A charge) Kg1110*210.5*210.5*2
    DimensionsHigh (mm)2296229622962296
    Width (mm)1006100610061006
    Long (mm)1436200620062006
    Weight (Kg)600900010001000
    Maximum water resistance (Kpa)50505050
    Piping interfaceAir conditioning water pipeDN40 flangeDN50 flangeDN50 flangeDN50 flange
    Domestic hot water pipeG1-1/4” inner screwG1-1/4” inner screwG1-1/4” inner screwG1-1/4” inner screw
    Gas piping (mm)Rc1/2”Rc3/4”Rc3/4”Rc3/4”
    Running noise dB (A)60616262
    FanAir supply formAxial Fan*1Axial Fan*2Axial Fan*2Axial Fan*2
    Rated air volume M3/h1500250002700027000

    Remark:

    1. Refrigeration: The outdoor temperature is 35°C, and the outlet water temperature is 7°C. When the outlet water temperature is lower than 5°C during operation, antifreeze must be used as the refrigerant water.

    2. The amount of heat recovery under refrigeration conditions: the outlet water temperature is 45°C. (Please note that this function is required when ordering)

    3. Heating (nominal): outdoor temperature 7/6°C, outlet water temperature 45°C; heating (low temperature): outdoor temperature 2/1°C, outlet water temperature 45°C.

    4. The type of gas is natural gas, and the pressure is low pressure. (Maximum pressure: 2.5kpa; Standard pressure: 2.0kpa; Minimum pressure 1.0kpa)

    5. Actual gas consumption (Nm3/h) = gas consumption (kW) X3.6/35.4 (MJ/Nm3)

    6. If the product is updated, the data is subject to change without prior notice.

    Buy 40KW Natural Gas Heat Pump Air Conditioner GHP High Reliability at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Qingdao Kingway Industry Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0