Categories | Walk In Test Chamber |
---|---|
Brand Name: | GSKA |
Model Number: | Walk In Test Chamber |
Certification: | CE SGS ROHS UL CE |
Place of Origin: | Dongguan China |
MOQ: | Negotiate |
Price: | Negotiate |
Payment Terms: | T/T, L/C |
Supply Ability: | 100 Set / Sets per Month |
Delivery Time: | 10-60days after confirmed payment or by contract stipulation |
Packaging Details: | Export package |
Humidity Range: | 20% ~ 98% RH |
Keyword: | Walk In Test Chamber |
Heat Up Rate:: | About 3℃~5℃/min; Can Be Custom |
Cooling Rate: | 0.7c~1.0c/Min (Average) |
Chamber Materials: | SUS#304 Stainless Steel For Internal Chamber |
Brand: | Walk In Test Chamber |
Test time: | 1~9999 minutes(arbitrary setting) |
Cooling rate: | 1 ℃ / min |
Galvanized Steel Sheet Exterior Walk In Test Chamber Multipane
Viewing Window With Heater
Related Testing Standard:
GB/Bb T2423.2-89 high temperature test method
GB2423.1-89 test A: low temperature test method 6
Ab IEC60068-2-1 low temperature test method
GJB150.4-1986 test at low temperature
EIA - 364-59 test at low temperature
IEC60068-2-38 temperature cycle
IEC60068-2-78 constant humidity temperature
MIL - STD – 202G – 103B humidity test
IEC60068-2-30 humidity temperature cycle
EIA - 364-31C wet resistance
GB/T2423.3 constant humidity heat test method
GJB150.4-86 military equipment environment test method for low temperature test
GJB150.3-86 military equipment environment test method for high temperature test
GB/T2423.34-2005 temperature and humidity combined cycle test method
GJB150.9-86 military equipment environment test method for humidity
temperature test
Optional accessories:
1. Cable Port: Two size of cable port is available: &50mm,
&100mm.
2. Double door
3. Pass room: Provided to avoid disturbance of atmospheric
temperature and humidity while opening the door.
4. Floor reinforcement: Can be fixed if heavy specimen placed in
the chamber for test.
5. Carry-in inclined platform: Provided below the door to
facilitate moving of specimens in and out through the door.
6. Entire ceiling blow-out duct
7. The extremely wide air inlet reduces the airflow rate (down to
apprrox.0.5m/s)
8. Dehumidifier
9. The rotation regenerating dehumidifier (M-300)ensures precise
control of low humidity (21°C,23%RH)for electrostatic reliability
tests.
10. Temperature and humidity recorder
11. 100mm width recording paper with 6 dots
12. 180mm width recording paper with 12 dots
13. Status indication lamp
14. Provide to signal chamber status and warnings when normal
running, a malfunction running or stand by occurs.
15. Water purifier
16. Provided to keep the humidifier heater free from scale and
ensure the supply of water to humidifier.
17. Power socket
Specifications:
Product Name | Walk in Environmental Chamber Temperature Humidity Test Chamber | |
Model | Walk-Ins | |
Internal dimension (mm) | As request | |
Overall dimension (mm) | As request | |
Temperature range | A: -20℃ ~+150 ℃ B:-40℃ ~+150 ℃ C:-70℃ ~+150 ℃ | |
Humidity range | 20% ~ 98% RH | |
Temperature fluctuations | ± 0.5 ℃ | |
Temperature deviation | ± 2.0 ℃ | |
Humidity deviation | ± 2.5% RH | |
Heating rate | 3 ℃ / min | |
Cooling rate | 1 ℃ / min | |
Temperature Sensor | PTR Platinum Resistance PT100Ω/MV A-class | |
Temperature Resolution | ± 0.001 ℃ | |
Humidity sensor | Dry and wet bulb sensor | |
Power Supply | AC220V 50HZ | |
Environmental conditional | 5℃~+40 ℃ ≤85% RH |
We keep good quality and competitive price to ensure our customers
benefit ; We respect every customer as our friend and we sincerely
do business and make friends with them,no matter where they come
from. Each batch of parts is done quality sampling inspection
before into the warehouse, and Each product before delivery is
tested by the national authoritative third-party inspection agency