KINGSINE KT210 120V PT CT Analyzer IEC61869-2 ANSI45 Standard
![]() |
KINGSINE KT210 120V PT CT Analyzer IEC61869-2 ANSI45 standard Discription of CT Tester Complete measurement function, it can test all type current transformer for secondary overload, secondary loop resistance, excitation characteristic, transient ......
Kingsine Electric Automation Co., Ltd.
|
Precision Current Transformer Analyzer / Power Transformer Testing Equipment
![]() |
CT PT Analyzer GF106T Ct/Pt Analyzer/Instrument Transformer Testing/Ta/Tv Analyzer /Pt Test System I. Current Transformer (CT) II. Voltage Transformer (PT) 1. Magnetization curve 1. Excitation characteristic test 2. Transformation ratio test 2. Transformation ratio test 3. Polarity 3. Polarity 4. 5% and 10% error curve 4. Withstand test of power frequency alternating current 5. Current......
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
|
IEC 60044 Electrical CT Analyzer Current Transformer Test Instrument
![]() |
Current Transformer CT Analyzer CT Testing Equipment Tester for current transformer: 1.Excitation curve and parameters test 2.Turns ratio test 3. Ratio and phase error test 4. Polarity mark check 5. Coil resistance measurement 6. Secondary loop burden measurement 7. Error line curve test for protection CT 8. Transient CT parameters test 9. CT nameplate guess 10.Saturation hysteresis loop curve measurement Applications of CT Current......
Advanced Instruments Co.,Limited
|
Current Transformer Analyzer / CT Analyzer
![]() |
... mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT nameplate guess 10 Saturation hysteresis loop curve measurement Tests for Voltage Transformer: 1...
Wuhan Huaying Electric Power Tech & Science Co.,ltd
|
Portable 1Phase CT Analyzer Test , 19.84 Lbs Current Transformer Tester
![]() |
... IEC61869-3(IEC60044-2), IEEE/ANSI C57.13 etc. test standards. It allows to test the knee-point voltage up to 40kV CTs and PTs on-site in power grids or in manufacturers' production facilities or test labs. Portable CT Analyzer CTP-200P is an all-in-one...
HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
|
CT Analyzer PT Analyzer
![]() |
CT PT Analyzer HYVA-405 Tests for Current Transformer: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT......
Wuhan Huaying Electric Power Tech & Science Co.,ltd
|
100V CT PT Test Equipment , 15A Current Transformer Analyzer
![]() |
Current Transformer Tester and Analyzer MCCT2000 Specifications Output Voltage Output 0~100V (AC) Current Output 0~15A (Peak) Measurement Current Measurement Accuracy ±0.1% Voltage Measurement Accuracy ±0.1% Secondary Side Voltage Measurement Input......
Zhengzhou Great Electric Co.,Ltd.
|
Single Phase Low Current CT Current Transformer 100 5a For Metering System
![]() |
... 0.66 rated voltage (kV). Mainly used for indoor, rated voltage of 0.66kV and below the rated frequency of AC circuit 50Hz as current and electric energy measurement and relay protection, products for the...
YUEQING YOMIN ELECTRIC CO., LTD
|
Supply Transformer CT/PT Analyzer Single Phase Excitation Ratio Testing
![]() |
...CT/PT Analyzer Single Phase Excitation Ratio Testing Product Description XHTX201D CT/PT ANALYZER is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, Degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current......
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
|
RSCTP Ct Pt Analyzer For Current Transformer And Voltage Transformer
![]() |
...CT PT Testing Instrument Analyzer for Current Transformer and Voltage Transformer Product Description CT/PT ANALYZER is mainly used for field testing of Current Transformer and Voltage Transformer. The test items mainly include excitation characteristic, transformation ratio, polarity, Degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current......
Wuhan Rising Electric Co., Ltd.
|