Pepperl-Fuchs Inductive Sensor NBB2-8GM50-E2 2 Mm Flush Increased Operating Distance Extended Temperature Range-40 ... +85 °C
![]() |
Technical Data General specifications Switching function Normally open (NO) Output type PNP Rated operating distance sn 2 mm Installation flush Output polarity DC Assured operating distance sa 0 ... 1.62 mm Actuating element mild steel, e. g. 1.0037, ......
Xiamen ZhiCheng Automation Technology Co., Ltd
|
24V DC Long Distance Inductive Proximity Sensor Switch For Metal Detection
![]() |
...Distance Inductive Proxmity Sensor Switch For Metal Detection Quick detail information of the sensor : Series : Long Range Inductive proximity sensor Size : D6.5*45mm Housing Material : stainless steel Mounting : shielded/Non-shielded Sensing Distance Sn(mm): 2mm/3mm/4mm/6mm Operating Voltage : DC 10-30V Output function : NPN/PNP NO/NC connection : 2M PVC cable Specification of the sensor : D6.5 long range inductive......
Luo Shida Sensor (Dongguan) Co., Ltd.
|
POM Inductive Sensors Output PNP NO Quasi Flush 2mm Detection Distance
![]() |
Inductive Sensors POM Output PNP NO Quasi-flush 2mm Detection Distance 10-30VDC Product Description The M8 inductive sensor is a compact, high-precision sensor primarily used to detect the presence or position of metal objects. It operates based on inductive......
Kronz (guangzhou) Electronics Co., Ltd.
|
P+F Inductive Sensor NBN40-U1-E2 0-32.4mm Assured Operating Distance
![]() |
Inductive sensor NBN40-U1-E2 Sensor head bidirectional and rotatable 40 mm non-flush < 3-wire DC 4 LEDs indicator for 360° visibility Datasheet excerpt: Technical data of NBN40-U1-E2 General specifications Switching function Normally open (NO) Output type PNP Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Actual operating distance......
SC Automation Limited
|
NPN Normally Closed Inductive Sensors With 3mm Detection Distance
![]() |
Inductive Sensor with 3mm Detection Distance and NPN Normally Closed Output This NPN normally closed (NC) inductive proximity sensor offers precise non-contact detection of metallic objects with a 3mm sensing range. Its NC (normally closed) circuit provides fail-safe operation......
Kronz (guangzhou) Electronics Co., Ltd.
|
P+F NBN40-U1-E2 Inductive Sensor 40mm Non-Flush 3-Wire DC NO
![]() |
Inductive sensor NBN40-U1-E2 Sensor head bidirectional and rotatable 40 mm non-flush < 3-wire DC 4 LEDs indicator for 360° visibility Datasheet excerpt: Technical data of NBN40-U1-E2 General specifications Switching function Normally open (NO) Output type PNP Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Actual operating distance......
SC Automation Limited
|
6mm Head NPN NO 1mm Metal Sensing Flush Inductive Sensor M8 Connector
![]() |
...Inductive Sensor M8 Connector Sensing Distance 1mm Standard Object 8×8×1(iron) Response Frequency 800Hz Hysteresis ≤10% sensing distance Operating Voltage 12~24VDC±10% (customize 5V) Current Consumption ≤8mA (No Load) Load Current 100mA Max at 24Vdc Circuit Protection Polarity Reverse Protection and Short-Circuit Protection Operating......
F&C Sensing Technology (Hunan) Co.,Ltd
|
Stainless Steel M4 Small Inductive Sensor Shielded Unthreaded Long Sensing Distance
![]() |
Stainless steel M4 ultra small inductive proximity sensor shielded unthreaded long sensing distance Technical parameter Size J4*25mm Mounting Shielded Sensing Distance SN [mm] 1/1.2/1.5 mm Housing material Stainless steel Indicator With LED Operating ......
|
Pepperl Fuchs Inductive sensor NBN40-U1K-N0 Sensor head bidirectional and rotatable
![]() |
... closed (NC) Output type NAMUR Rated operating distance 40 mm Installation non-flush Assured operating distance 0 ... 32.4 mm Actual operating distance 36 ... 44 mm Reduction factor rAl 0.45 Reduction factor rCu 0.45 Reduction factor r304 0.8 Output ......
Achievers Automation Limited
|
PEPPERL FUCHS NJ3-18GK-S1N Inductive sensor 3mm Rated Operating Distance
![]() |
...V1 Inductive sensor General specifications Switching function Normally open (NO) Output type NAMUR with safety function Rated operating distance 3 mm Installation flush in mild steel Assured operating distance 0 ... 2.4 mm Actual operating distance 2.7 ......
Achievers Automation Limited
|