Sign In | Join Free | My chinaqualitycrafts.com |
|
Categories | Electrical Appliance Testing Equipment |
---|---|
Brand Name: | Sinuo |
Model Number: | SN1104-20KV |
Certification: | Calibration Certificate (Cost Additional) |
Place of Origin: | China |
MOQ: | 1 |
Price: | Negotiable |
Payment Terms: | T/T |
Supply Ability: | 10 sets per month |
Delivery Time: | 25 Days |
Packaging Details: | Plywood case |
High peak voltage: | 2,500v~20,000v |
Low peak voltage: | 300V~2500V |
Output polarity: | Positive and negative |
Impulse wavefront time: | 1.2 µs ± 30 % |
Half wave time: | 50 µs ± 20 % |
Instrument internal resistance: | ITU-T K.44 |
Impact interval time: | 10 ~ 99s |
Impact cycles time: | 1 ~ 9999 |
Company Info. |
Sinuo Testing Equipment Co. , Limited |
Verified Supplier |
View Contact Details |
Product List |
IEC 62368-1 Clause 5.4.2 20KV Impulse Voltage Generator And Voltage Waveform Attenuator Test Equipment
Product Information:
Standard: Conform to IEC 62368-1:2018 clause 5.4.2,5.5.8 and Annex D, circuit 1 and circuit 2 of Table D.1, Annex G.10, etc., IEC 60950-1:2013 clause 2.10.3.9, 5.2, reference 2 of table N.1, IEC 60950-1:2013 clause 6.2.2.1 and 7.4.3 reference 1 of table N.1, and etc.
Application: It is used to detect the transient over voltage of the components and the electrical clearance and the creepage distance.
Test sample: Household appliance, Audio, video and similar electronic apparatus.
Feature: The sample breakdown will produce a spark and acoustic, instrument peak voltage than the no-load voltage is decreased substantially (close to zero), when applying the same voltage in the next test, it will also show the above phenomenon.
Technical Parameters:
Model | SN1104-20KV |
DC high voltage | Max. 20kV |
Impulse voltage wave | Impulse wavefront time: 1.2 µs ± 30 %; Half value of after wave time: 50 µs ± 20 % Please note that the waveform should be checked on an external oscilloscope |
Instrument internal resistance | Resistance matches ITU-T K.44 |
Peak voltage: | Low: 300V~2,500V; High: 2,500 V~ 20,000V |
Impact interval time | 10 ~ 99s |
Impact cycles | 1 ~ 9999 |
Polarity | Positive and negative |
Working power source | Rated voltage: ~ 220V±10%, 50/60Hz |
![]() |