Categories Portable Reference Standard
Certification: ISO, CE
Supply Ability: 300/Year
Payment Terms: L/C, T/T, D/P
Brand Name: GENY
Model Number: YC98S1
Place of Origin: CHINA
Model NO.: YC98S1
Display: Digital
Installation: Direct Connected
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment: Three-phase Three-wire
Theory: Electronic Meter
Power Meter Connection: Terminal
Measured Signal: Continuous Wave
Type: Energy Meter
Customized: Customized
Trademark: GENY
Transport Package: Carton
Origin: China
HS Code: 9030849000
Port: Guangzhou, China
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Customized Yc98s1 Energy Meter Calibrator Three Phase For Measuring Needs

Customized Yc98s1 Portable Three Phase Standard Meter Test Machine for Measuring Needs

YC98S1 Portable 3 Phase Standard Meter

The instrument YC98S1 is used to calibrate three phase, single phase, active or reactive energy
meter who comply with GB/T17215.211 (IEC62052-11), GB/T17215.311 /321/322/323
(IEC62053-11/21/22/23), and also it can be used as voltage, current and power meter to measure
AC parameter of three phase power grid.
This portable three phase standard meter comply to GB/T11150-2001 (IEC60736:2001),
GB/T4793.2-2008 (IEC61010-1:2001).

Test functions

  1. Can test one meter or two meters at the same time.

  2. Automatic test sequence using the scanning head for electronic and electromechanical meters

  3. Can synchronously calculate all data and display on the interface include full wave

  4. Can test active and reactive energy accuracy of full wave meter

  5. Can simultaneously test two channel pulses whose pulse constant

  6. Wiring identification is available when no load.

  7. Electric energy accumulation function can measure the electric energy meter when it has not pulse output.

  8. Dial test function

  9. Display vector diagram

  10. Can identify wrong wiring (48 types connections)

  11. Instrument can be simulate the scene of variety of wiring and get corresponding the result of wiring and revised parameter in office without access to voltage or current signal situation

  12. Harmonic functions

Specifications


Test Voltage (Full Wave & Fundamental Wave)
Range0~500V
Error±0.05% (0.1%)
Harmonic2nd ~ 51st
Test Current (Full Wave & Fundamental Wave)
Range (direct connection)0.025A ~ 12A (Ie=5A)
Range (100AClamp CT)

0.5~120A (Ie=100A,usage range=0.01Ie~2.4Ie)

(Optional: Ie=5A, 500A, 1000A)

Error (direct connection)±0.05% (0.1%)
Error (100AClamp CT)±0.2%(5A,100A) ±0.5% (other)
Harmonic2nd ~ 51st
Starting current0.05%Ie
Power Measure Error (Full Wave & Fundamental Wave)
Active Power (Direct connection)±0.05%
Active Power (100A ClampCT)±0.2%(5A,100A) ±0.5% (other)
Reactive Power (Direct connection)±0.1%
Reactive Power (100A ClampCT)±0.5%(5A,100A) ±1.0% (other)

Energy Measure Error (Full Wave & Fundamental Wave)
Active Energy (Direct connection)±0.05% (±0.1%)
Active Energy (100A ClampCT)±0.2%(5A,100A) ±0.5% (other)
Reactive Energy (Direct connection)±0.1%
Reactive Energy (100A ClampCT)±0.5%(5A,100A) ±1.0% (other)
Error (Harmonic Wave)
Direct ConnectionkWh,U, I, P, Q, S±0.2%H (H=1+0.01k, k=2~51)

Clamp CT

5A/100A

kWh,U, I, P, Q, S±0.5%H (H=1+0.01k, k=2~51)
Cycle Output Current for 5A CCT’s Self Calibration0.05A,0.1A,0.25A,0.5A,1A,2.5A,5A

Error of 5ACCT’s Self Calibration

(linear and phase error)

±0.1%
Clamp CT 500A/1000AkWh,U, I, P, Q, S±1.0%H (H=1+0.01k, k=2~51)
Error - Others
Ratio Measurement±0.5%
Voltage Influence<±0.01%
Frequency Influence<±0.01%
Temperature Influence<±0.01%/℃
24h Accuracy Influence<±0.01%
Harmonic Influence<±0.01%
Phase angle
Range- 180°~ 180°
Error<±0.1°
Frequency
Range45 ~ 65Hz
Error±0.01Hz
Pulse output
Inner High frequency (CH)Direct connection1.8x109 P/kWh
Clamp CT1.8x109 *(5/Ie)P/kWh
Low frequency outputDirect connection

3600P, 36000P,

360000P/kWh(kvarh, kVAh)

Clamp CT

3600P, 36000P,

360000P

*(5/Ie)P/kWh(kvarh, kVAh)


Pulse ratio1:1
Output level+5V (can be adjusted according to request)
Pulse input
Input Channel2
Input level5 ~ 10V
Max Pulse Input frequencyMax. 10kHz
Display
Resolution7’’TFT Touch Screen
SystemWindows CE
Other
Voltage supply modeExternal power, Tested circuit, Battery
Working power supplyAC 55~600V
Voltage Withstand4.0kV (voltage ¤t terminals, power supply & low voltage terminals)
EFT(Electrical Fast Transient)2.0kV
IP LevelIP51
Surge2.0kV (common mode), 2.0kV (different mode)
Power on Stability Time< 3mins
Chargeable battery11.1V 3000mAh
Power Consumption<9W
Operation TemperatureTemperature -20℃ ~ +55℃, humidity 40% ~ 95%
Storage TemperatureTemperature -40℃ ~ +80℃, humidity 40% ~ 95%
Dimension (mm) (W×H×D)Main245×150×50
Carry case425×336×196
Weight (kg)Main2
Whole set10